Visit the mobile phone station
————
CONTACT US
————
GUANGDONG JINZE ELECTRIC(GROUP) CO.,LTD.
Canadian company
Address: 1020, 4385-104 Ave SE Calgary, AB T2C 5C6
Email:rachel_goldentop@163.com, kit_goldentop@163.com
Jinze Electric Group was established in 1982 and is a global leader in manufacturing High & Low Voltage switchgear and electrical control equipments. Its two main subsidiaries, Xinhui Electric Control Equipment Factory Co. Ltd and Jiangmen Golden Top Automation Co., Ltd were established in 1981 and 1998 respectively. Our main products are high-voltage and low-voltage switchgears, electrical control assembling equipment, electrical communication assembling equipment and network racks, etc.
GUANGDONG JINZE ELECTRIC(GROUP) CO.,LTD.
ABOUT JINZE
-
Begin
Staff
Advanced equipment
Area covered
Adhere to the development orientation of quality service
PRODUCTS CENTER
————

8BK18HIGH-VOLTAGESWITCHGEARTECHNICALSPECIFICATION 1、 PROUCTGENERALDESCRIPTIONKYN□(8BK18)-12(Z)metal-cladremovabletypeACswitchgeardeviceisthe8BK18typeswitchgearwhichis authorizedbySiemenstoproduceandsell,whichisadvancedproductwithinternationalstandardthroughcontinuousimprovementanddesign,isabletofullymeetthedemandofsubstation,powerplant,andisagoodcompanionforasafepowerdistribution.KYN□(8BK18)-12(Z)metal-cladremovabletypeACswitchgeardevicemeetsthestandardsofIEC,GB,DL,DINVDEandpassthecomprehensivelytypetestofinternalhigh-voltagetestcenter.Itsupportsareasonabledesign,reliableperformance,contemporarywiththeadvancedinternationallevel,tobettermeettherequirementinhighreliabilityforuser,andhaverelatedproductcertificate. 2、APPLICATIONSCOPEKYN□ (8BK18)-12(Z)metal-cladremovabletypeACswitchgeardeviceiswidelyusedinthe variousfields,suchaspowerplants,high-voltage/middlesubstationandhighcapacitymiddlesubstation,substationsystem,industrialandminingenterprises,civilbuildinginfrastructuresetc. 3、STANDARDSKYN□(8BK18)-12(Z)metal-cladremovabletypeACswitchgeardevicemeetthefollowinginternationalandinternalstandards: IEC60694&GB11022GeneralTechnicalConditionforHVSwitchgearDeviceIEC60298&GB3906-913~35kVACMetalcladSwitchgearDeviceIEC60056&GB1984HVACBreakerDL/T403-2000OrderTechnicalConditionfor12~40.5kVHVVacuumBreakerDL/T593-1996OrderTechnicalConditionforHVSwitchgearDeviceSD318-1989 TechnicalConditionforHVSwitchgearLockingDeviceDL/T404-1997OrderTechnicalConditionforOutdoorACHVSwitchgearDeviceIEC298-19901kVabove&52kVorbelowACMetalcladSwitchgearDeviceandControlDeviceGB50171-1992ElectricalInstallationPanel,cabinetandsecondaryreturncircuitwiringandacceptanceinspectionspecification 4、MAINTECHNICALDATA:4.1CONDITIONFORNOMALUSELocationofInstallationOutdoor,canchoosewall-mountedinstallationornonwall-mountedinstallation(rearopendoorexamineandrepair)MinimumTemperature-15℃ (35℃ isallowedtodelivery)MaximumTemperature+45℃24HourAverageTemperatureDifference+35℃Abovesealevel≤1000mDailyAverageValueofRelatedHumidity≤95%MonthlyAverageValueofRelativeHumidity≤90%DayDifferenceinTemperature≤15KEarthquakeResistanceCapacityNotoverthan8degree,levelacceleration0.3g,safetyfactor1.67.Usesinewaveresonancetestmethod,sharpshake5times,5wave,spacing2SWirelessInterferenceLevelVoltageislessthan500μVwithinterferedbywireless1.1timesU/,Uistheratedvoltageoftheproduct.DirtinessClassClassII 4.2、ElectricalDataRatedVoltage(Max.Voltage)12kVRatedFrequency50HzRatedCurrent1250A,1600A,3150A,4000ASwitchingCurrentofRatedShortCircuit(effectivevalue)31.5kA,31.5kA,40kA,40kA(or50kA)RatedThermalStabilizedCurrent(effectivevalue,4s)31.5kA,31.5kA,40kA,40kA(or50kA)RatedThermalStabilizedCurrentandShort-circuitSwitching-onCurrent(peakvalue)80kA,80kA,100kA,100kA(or125kA)RatedInsulationVoltage1minPowerFrequencyWithstandVoltagePhasetoground,phasetophase42kV,onceseparatefracture48kVLightningImpulseWithstandVoltage(peakvalue)Phasetoground,phasetophase75kV,onceseparatefracture85kVSecondaryLoop1minpowerfrequencywithstandvoltage2kV;InsulationResistance(1000V)≥1MΩAirnetspacebetweendifferentphaseconductor,Airnetspacebetweenconductorandearthing.≥125mmExteriorInsulationCreepingDistanceofEachcomponentsincabinetandtheirsupportinsulationpartsPureporcelaininsulationparts≥18mm/kV(ExteriorInsulationCreepingDistance:≥216mm)Organicinsulationparts≥20mm/kV(ExteriorInsulationCreepingDistance:≥240mm)(Meettheelectricalstandard“DL/T404-1997 OrderTechnicalConditionforOutdoorACHVSwitchgearDevice”Type2DesignSpecification.DesignClassClass2StandardDegreeofProtectionTheprotectingdegreecanreachIP4X,whenthedoorofthecarriercompartmentisopened,theprotectingdegreewillbeIP2X. 4.3、OverallDimensionRatedDataH(mm)W(mm)D(mm)TopEntryBottomEntry1250A2300800166015002500A2300900166015003150A23001000166015004000A2300100016601500 5、Structure5.1Using2~3mm aluminiumandzinccoatedandimportedhotgalvanizedsteelplate withstrongcorrosion.Resistance,aswellasthedoublebendingprocess,enablethestrengthofthecasebodytobegreatlyimproved. 5.2Theswitchgearconsistoftwomajorportions:fixedcasebodyandwithdrawablecarries.Thepartitions,usedfortheenclosureandfunctionalunits,aremadefromhotgalvanizedoraluminiumcoatedsteelsheets,whichareprocessedwithnumericalcontrolledmachinetool,thenbebentandboltedtotakeshape,.Insidetheswitchgear,therearecircuitbreakercompartment,busbarcompartment,cable-compartmentandlowvoltagecompartment.Forthedistributionofdifferentfunctionalelementsandassemblyofprincipalelectricalcomponents. 5.3 Respectively,thereisarelievingdeviceoverthecircuitbreakercompartment,busbarcompartmentandcablecompartment.Whenthefailure,followedwithelectricarcoccursinacertaincompartments,causingtheriseofpressure,therelievingdevicewillbeactuatedandtherelievingplateopensautomatically,andthepressureandgasarerelieved,thusensuringthepersonalsafetyoftheoperators.Onthetopofthehighpressureroomoftheswitchgear,exhaustdeviceareprovided.Whenpressureinsidethecabinetisboostedbecauseofmalfunctionelectricarc,thepressureexhaustdeviceonthetopwillbeautomaticallyopened.Sincethedooroftheswit

technicalspecificatonOFBLOKSETLOW-VOLTAGESwitchgearcabinet 1、GENERALBLOKSETLVswitchgearcabinetisthelatestLVwholesetswitchgearequipmentpromotedbyResearchCenterofSchneiderElectricCompanyFrancewithhighquality&high-power.Makinguseoftechnicaladvantage&highqualityofelectriccomponentLVswitchequipmentproducedbySchneiderCompany,itsupportsareasonabledesign,reliableperformance,contemporarywiththeadvancedinternationallevel,tobettermeettherequirementinhighreliabilityforuser,andhaverelatedproductcertificate.OurcompanyhasbeendoingbusinesswithSchneidercompanyandintroduceintothewholetechnologyofthisbrandcabinetsstartedmanufacturingtheBLOKSETLVswitchgearfrom2003.2、ApplicationScopeBLOKSETLVswitchgearequipmentsuitforpowerplantsandsubstations,industrialandminingenterprises,civilconstructionandairportrailwaywatersupply,roadconstructionandotherinfrastructurefields,asadynamicdistributioncenter,motorcontrolcenter,capacitancecompensationandotherterminalpowerdistributioncontrol,conversionanddistributiondevices. 3、ComplianceStandard:BLOKSETswitchgeariscompliancewiththefollowinginternationalanddomesticstandard.IEC439-1/VDE0660/DIN41-488/EN60439-1/BS5486-1/UTE63-412/IEC364/DIN0100GB7251-1-97 《Low-voltageCompleteSetofSwitchDeviceandControlEquipment》GB/T4048-1-93 《GeneralSpecificationofLow-voltageCompleteSetofSwitchDeviceandControlEquipment》GB7947-87 《ColorSymbolforInsulativeConductor andBareConductor》JB/T9661-99 《Low-voltageSwitchWithdrawableCompleteSetofSwitchDevice》JB4012-85 《Low-voltageAirTypeIsolator,Switch,IsolationSwitchandFuseAssembledElectricEquipment》IEC112:1979 《TestingMethodofSolidInsulatedMaterialintheconditionofRelativeMarkingIndex》IEC68.3.3 《ShockResistanceTesting》 AS3439-1 《InternalArcWithstand》GB3983-1-89 《Low-voltageParallelConnectionCapacitor》AllareTTAProductwhichhaspassedcomprehensivelythetypetest(IEC439-1) 4、MainTechnicalData:(1)EnvironmentalConditions:q Altitudeabovesealevel:≤2000m(higherthan2000mshouldconsiderreducingthecapacity)q Environmentaltemperature:-15℃-+60℃q RelatedHumidity:10%-90%q SaturatedSteamPressure: lessthan2.2X10-3Mpaq Seismicresistancecapacity: ≦8degree(Horizontaldirection0.5g,Verticaldirection0.3g)q Installation:Indoortype,thegradientbetweenverticalinstallation&verticalplanecannotexceed5degree.(2)ElectricData:q RatedInsulationVoltage:AC1000Vq RatedOperatingVoltage:AC690Vq TestingVoltage:AC3500Vq RatedLightningImpulseWithstandVoltage:12kVq ThermalStabilizedCurrent:100kARMS/1Sq DynamicStabilizedCurrent: 220KA(Peak)q MainBusbarsMax.OperatingCurrent:6300Aq MaximumOperatingCurrentofDistributionBusbars: 6300Aq RatedVoltageofAuxiliaryCircuit : AC220Vq TypeofDistributionSystem: TN-SBusbars(IndividualWireNandWirePE)q TypeofSystemEarthing: Directlyearthinginthecenterq RatedFrequency: 50Hzq ElectricInterval: 14mmq Creepage-Length: 16mmq IsolationInterval: meettherelatedrequirementofJB4012-85q WithstandVoltageLevel: 2.5kV50Hz1minq TemperatureRise: meettherelatedrequirementofIEC947-1、GB7251-1997(3)MechanicalData:q ProtectionDegree: IP4Xq TypeofInteriorCompartment: Type1/2b/3b/4q TypeofInstallation: Maybeinstalledawayfromwallorleaningagainstthewall.q Incoming&FeederMode: TopEntryTopFeeder/TopEntryBottomFeeder/BottomEntryBottomFeeder/BottomEntryTopFeederq CabinetHeight: 2200mmq CabinetDepth: 400/600/1000mmq CabinetWidth: 700/900/1100/1200/1300mmq SurfaceTreatment: HeatPolyesterEpoxideResinPowdercoating 5、MainCharacteristicBLOCKSETswitchgearisthesealedandindoorequipment,theenclosureandswitcharedesignedbySchneider,suchasMasterpactMTFrameCircuitBreaker,CompactNSmoulded-casecircuitbreaker,withlargecapacityspecifications,advancedtechnologyforswitchstructure,mature&reliableprocessingtechnique,compactstructure,easyinstallationandmaintain,etc. l Theswitchgear,consistofframe,coverplate,coveranddoor,canwithstandthemechanicalandthethermalloadfunctionwhichthesystemshort-circuitsproduces,canwithstandimpulseproducedbyswitchmotion¬affecttheoperationofotherelectricappliance,alsocanwithstandthestressfunctionofnormallifting,transportation&maintainitsperformancenottobeaffected.Theswitchgearandallcomponentandmaterialinsideshallbeflame-retardantornon-inflammable.Thedesignandmaterialusedcanpreventtheoccurrenceofbreakdownelectricarcinthegreatestdegree,oncetheelectricarcwentwrong,itcanextinguishinashorttime.TheROHSplasticmaterialusedintheswitchgearexcludesCFC&Halogenbeingflame-resistantandfromextinguishmentcharacteristic,canenhancetheprotectiongradeinsidetheswitchgearandreliable&continuousoperation.l Canbeeasilyextendedwithbothends(ifthejobsiteisallowed)l Themechanicalinterlockisequippedinthecabinet,ensurethatthedoorofcabinetcannotbeopenedwhenclosingtheswitch.l Completelyusethestandardparts,speciallydesignfordifferentprojectisnotexisted,ensuretheinterchangeabilityandstability.Thistypeofcabinetisstandardizationandhavehundredsofstandardschemewhichcanmeetth
ENGINEERING CASE
————
NEWS CENTER
————